← All products

PANEL MOUNT / THREE-PHASE / DC–AC

MGR-3 032
38/48 Series

DC-control, AC-output three-phase solid state relays with integrated three-channel switching and zero-cross operation.

Ask about this series ↗
MGR-3 032 3840Z straight front view
MGR-3 032 3840Z · 40 A representative model
01 / MODEL RANGE

Nine current options.

Each number is the maximum rated load-current value. Continuous usable current depends on the heat sink, ambient temperature, duty cycle and installation.

MGR-3 032 3810ZMAX RATED LOAD CURRENT10 A
MGR-3 032 3825ZMAX RATED LOAD CURRENT25 A
MGR-3 032 3840ZMAX RATED LOAD CURRENT40 A
MGR-3 032 3860ZMAX RATED LOAD CURRENT60 A
MGR-3 032 3880ZMAX RATED LOAD CURRENT80 A
MGR-3 032 38100ZMAX RATED LOAD CURRENT100 A
MGR-3 032 38120ZMAX RATED LOAD CURRENT120 A
MGR-3 032 38150ZMAX RATED LOAD CURRENT150 A
MGR-3 032 48200ZMAX RATED LOAD CURRENT200 A
02 / PRODUCT VIEWS

See every side.

Four white-background views of the MGR-3 032 3840Z from the official MGR product archive.

MGR-3 032 3840Z front view
01 · Front
MGR-3 032 3840Z three-quarter view
02 · Three-quarter
MGR-3 032 3840Z side view
03 · Side
MGR-3 032 3840Z metal base plate
04 · Metal base plate
03 / PARAMETERS

Complete electrical reference.

Catalogue values for the MGR-3032 series. The listed current is the maximum rated load current; confirm the exact model and thermal setup before design-in.

Product familyMGR-3032 Series (DC to AC)
Switching functionThree-phase DC control / AC load
Output componentTRIAC, integrated three-channel output
Representative modelMGR-3 032 3840Z · 40 A maximum rated load current
Control voltage3–32 V DC (3, 5, 9, 12, 18, 24 and 32 V DC options; custom control voltage available)
Control currentUltra-low input current, ≤ 20 mA
Load voltageThree-phase 24–480 V AC (24, 48, 110/120, 220/230, 380, 415 and 480 V AC options)
Series current range10, 25, 40, 60, 80, 100, 120, 150 and 200 A maximum rated models
Switching modeZ suffix: zero-cross turn-on; blank or P suffix: random turn-on
Status indicationLED output-status indicator
Output circuitStandard RC snubber; low off-state leakage current and low on-state voltage drop
ProtectionTransparent terminal cover
Dimensions105 × 74 × 33 mm
Mounting and terminalsPanel / chassis mount, metal base and screw terminals; six M5 load terminals
Typical applicationsCommercial and heavy-industrial three-phase switching
04 / DIMENSIONS & SCHEMATIC

Dimensions and wiring principle.

The official drawing combines the mechanical dimensions with the three-phase DC-control wiring schematic. All dimensions are in millimetres.

MGR-3 032 dimensional drawing and DC-control three-phase wiring schematic
105 × 74 × 33 mm · six M5 load terminals · 3–32 V DC control input · delta or star-connected three-phase load

NEED A MODEL-SPECIFIC DATASHEET?

We can help confirm the right three-phase relay and thermal setup.

sales@mgrssr.com ↗